What is a benchtop freeze dryer?
1. 7" colour LCD screen for operation, LCD liquid crystal display, easy to operate and clear display.
2. Display control screen tilt degree, ergonomic design, more comfortable sense of operation.
3. One-piece structure design, small size, easy to use and no leakage.
4. Cold trap and operating table surface made of stainless steel, anti-corrosion, easy to clean.
5. All stainless steel filling (drain) valve, safe, anti-corrosion, no leakage.
6. Large cold trap opening, no inner coil, with sample pre-freezing function, no need for low temperature refrigerator.
7. Reasonable structure design of the cold trap, the cold trap traps ice evenly, strong ice trapping ability.
8. International standard vacuum pump interface, can be used with a variety of vacuum pumps.
9. International famous brand compressor, high efficiency and energy saving, long service life, low noise.
10. Famous brand vacuum pump, large pumping speed, achieve higher ultimate vacuum degree.
11. Intelligent data recording system, real-time recording and display of cold trap temperature curve, sample temperature curve and vacuum curve.
12. Large memory storage, historical data at a glance, equipped with USB interface, can export data through the computer to browse and print and a variety of operations.
A Type Benchtop Freeze Dryer | B Type Benchtop Freeze Dryer |
C Type Benchtop Freeze Dryer | D Type Benchtop Freeze Dryer |
How to use the benchtop freeze dryer?
To ensure that the vacuum freeze dryer can achieve the ideal freeze drying effect and extend its service life, please pay attention to the following matters.
1. The temperature and humidity of the operating environment of the freeze dryer should be maintained at 10℃-30℃ and the relative humidity should be <80%.
2. The working environment of the freeze dryer should be free from conductive dust, explosive, corrosive gas and strong electromagnetic field interference.
3. When the accumulated working time of vacuum pump reaches 200 hours or the colour of vacuum pump oil turns brown, the pump oil should be replaced in time. Prevent the vacuum pump from malfunctioning.
4. Please do not switch the refrigerant on and off frequently, and wait at least 3 minutes after the refrigeration machine is shut down before restarting it to prevent the refrigerant from being damaged.
5. When shutting down the machine, inflate it first and then turn off the vacuum pump to prevent the vacuum pump from returning oil to contaminate the sample.
6. The connection between the plexiglass drying barrel and the host is sealed by silicone sealing ring, the sealing ring should be kept clean to prevent scratching, and the plexiglass should not be wiped with organic solvent.
7. After using the freeze dryer, the moisture inside the cold trap should be wiped clean.
Technical parameters of benchtop freeze dryer
Model | FT1200-A | FT1200-B | FT1200-C | FT1200-D |
General type | Multi-flasking type | Gland type | Multi-flange gland type | |
Freeze-drying area (m²) | 0.12 | 0.12 | 0.09 | 0.09 |
Water catching capacity (kg) | 3 | 3 | 3 | 3 |
Eggplant bottle (pcs) | / | 8 | / | 8 |
Tray of solution (L) | 1.5 | 1.5 | 1 | 1 |
Size of material tray (mm) | φ200 | φ200 | φ200 | φ200 |
Number of material trays (pcs) | 4 | 4 | 3 | 3 |
Cold trap size (mm) | φ222×200 | |||
Cold trap minimum temperature | -58℃ | |||
Ambient temperature | ≤30℃ | |||
Vacuum degree | 1~5 pa | |||
Power | 220V50Hz/0.9(kw) | |||
Outer size(mm) | (W*D*H)493*363*586 |